Homepage of Susanne Kromnik
Research Group Leader
NameMs Dr.-Ing. Susanne Kromnik
Perfusion Technology Group
Send encrypted mail via the SecureMail portal (for TUD external users only).
Visitor Address:
Fetscherforum (F29), 1st Floor, Room 36 Fetscherstr. 29
01307 Dresden
SHORT BIOGRAPHY
since 2022 |
Technische Universität Dresden |
2012-2022 | Technische Universität Dresden Research Associate and Doctorate (Dr.-Ing.) in Electrical Engineering at the Institute of Biomedical Engineering |
2006-2011 |
Technische Universität Dresden |
PUBLICATIONS
2023
-
Characterization of time-delay in inline blood gas sensors , 8 Sep 2023, Biomedical Engineering / Biomedizinische Technik: Abstracts of the 57th Annual Meeting of the German Society of Biomedical Engineering 26 – 28 September 2023, Duisburg, including: The Artificial Vision Symposium – The International Symposium on Visual Prosthetics. s1 ed., Berlin, Boston: De Gruyter, Berlin [u. a.], Vol. 68. p. 214, 1 p.Electronic (full-text) versionResearch output: Contribution to book/conference proceedings/anthology/report > Conference contribution
-
Clinical evaluation of normothermically perfused porcine kidneys with autologous whole blood , 10 Feb 2023, In: European Urology. 83, Suppl 1, p. S587 - S587, 1 p.Electronic (full-text) versionResearch output: Contribution to journal > Meeting abstract
2022
-
Machine-derived data and molecular markers as indicators of organ quality in normothermic machine perfusion with whole blood , Feb 2022, In: European urology. 81, S1, p. S1599-S1599Electronic (full-text) versionResearch output: Contribution to journal > Meeting abstract
-
ASYS-Transplant: Die Entwicklung eines Assistenzsystems zur Evaluation marginaler Nieren während der normothermen Maschinenperfusion mit Vollblut im Großtiermodell , 2022, p. 59, 1 p.Electronic (full-text) versionResearch output: Contribution to conferences > Abstract
-
Biomarkers of kidney damage correlate with macroscopic quality of porcine kidneys during normothermic whole blood machine perfusion , 2022Research output: Contribution to conferences > Abstract
-
Investigation of the Drift Characteristics of Inline Blood Gas Sensors , 2022Research output: Contribution to conferences > Abstract
-
Molekularbiologische Untersuchungen an normotherm perfundierten porcinen Nieren zur Evaluation eines neuentwickelten Perfusionssystems mit Vollblut , 2022Research output: Contribution to conferences > Abstract
-
Neutrophil gelatinase-associated lipocalin (NGAL) and N-acetyl-a-d-glucosaminidase (NAG) reflect macroscopic injury during normothermic machine perfusion with whole blood , 2022, Abstracts of the 31st Annual Meeting of the German Transplantation Society (DTG 2022). Erlangen: German Transplant Society, p. 97 - 98, 2 p.Electronic (full-text) versionResearch output: Contribution to book/conference proceedings/anthology/report > Conference contribution
2021
-
Inulin Clearance During Ex vivo Normothermic Machine Perfusion as a Marker of Renal Function , 22 Dec 2021, In: ASAIO journal : official journal of the American Society for Artificial Internal OrgansElectronic (full-text) versionResearch output: Contribution to journal > Research article
-
THE SUITABILITY OF THE CLASSICAL KIDNEY INJURY MARKERS NGAL, KIM-1 AND NAG AS EARLY MARKERS OF REPERFUSION INJURY IN PORCINE KIDNEYS DURING NORMOTHERMIC WHOLE-BLOOD PERFUSION , Oct 2021, In: Transplant international. 34, S2, p. 26-26, PO-070Electronic (full-text) versionResearch output: Contribution to journal > Meeting abstract