Equipment
Analysis Flow Cytometers
LSR Fortessa (BD)
- measurement of 20 parameters: 18 fluorescence detectors, FSC and SSC
- 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (640nm)
- fully automated and rapid sample acquisition (HTS, only at 3rd floor)
- LSR Fortessa Configuration
- CRTD 1st floor south, room 1.229
- 0351-458-82138
- CRTD 3rd floor south, room 3.113
- 0351-458-82368
LSR II (BD)
- measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
- 3 lasers: Violet (405nm), Blue (488nm), Red (640nm)
- optional: fully automated and rapid sample acquisition (HTS)
- LSRII Configuration
- CRTD 1st floor north, room 1.229
- 0351-458-82138
- CMCB FCCF E-Mail
FACSCanto II SORP (BD)
- measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
- 3 lasers: Blue (488nm), Yellow-Green (561nm), Red (635nm)
- optional: fully automated and rapid sample acquisition (HTS)
- Canto II SORP Configuration
- CRTD 3rd floor south, room 3.112
- 0351-458-82368
- CMCB FCCF E-Mail
MACSQuant 10 (Miltenyi)
- measurement of 9 parameters: 7 fluorescence detectors, FSC and SSC
- 3 lasers: Violet (405nm), Blue (488nm), Red (635nm)
- automated sample acquisition (tube rack or well plates)
- integrated magnetic pre-enrichment option
- MACSQuant 10 Configuration
- CRTD 1st floor north, in front of room 1.229
- 0351-458-82138
- CMCB FCCF E-Mail
MACSQuant VYB (Miltenyi)
- measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
- 3 lasers: Violet (405nm), Blue (488nm), Yellow-Green (561nm)
- automated sample acquisition (tube rack or well plates)
- integrated magnetic pre-enrichment option
- MACSQuant VYB Configuration
- CRTD 3rd floor south, room 3.112
- 0351-458-82368
- CMCB FCCF E-Mail
Spectral Flow Cytometer
Aurora (Cytek)
- measurement of 67 parameters: 64 fluorescence detectors, FSC and blue SSC and violet SSC
- 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (640nm)
- Aurora Configuration
- CRTD 3rd floor south, room 3.113
- 0351-458-82368
- CMCB FCCF E-Mail
Cell Sorters
FACSMelody (BD)
- measurement of 10 parameters: 8 fluorescence detectors, FSC and SSC
- 3 lasers: Violet (405nm), Blue (488nm), Yellow-Green (561nm)
- sorting into different tubes, well plates
- Melody Configuration
- CRTD 3rd floor south, room 3.113
- 0351-458-82368
- CMCB FCCF E-Mail
FACSAria II SORP (BD)
- measurement of 16 parameters: 14 fluorescence detectors, FSC and SSC
- 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
- sorting into different tubes, well plates and onto microscope slides
- Aria II Configuration
- CRTD 1st floor north, room 1.229
- 0351-458-82138
- CMCB FCCF E-Mail
FACSAria III (BD)
- measurement of 18 parameters: 16 fluorescence detectors, FSC and SSC
- 4 lasers: Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (633nm)
- sorting into different tubes, well plates and onto microscope slides
- Aria III Configuration
- CRTD 3rd floor south, room 3.113
- 0351-458-82368
- CMCB FCCF E-Mail
FACSAria Fusion (BD)
- fully enclosed in a (Class II Type A2) Biosafety Cabinet
- measurement of 20 parameters: 18 fluorescence detectors, FSC and SSC
- 5 lasers: UV (355nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (640nm)
- sorting into different tubes, well plates and onto microscope slides
- Aria Fusion Configuration
- CRTD 1st floor north, room 1.223
- 0351-458-82124
- CMCB FCCF E-Mail
Imaging Flow Cytometry
ImageStreamX Mark II (Amnis/Millipore)
- the Imaging Flow Cytometer combines high throughput, quantitative and sensitive single cell analysis of a Flow Cytometer with microscopic imaging and spatial resolution
- 6 lasers: Violet (405nm), Blue (488nm), YellowGreen (561nm), Orange (592nm), Red (642nm), farRed (785nm)
- measurement of 12 parameters: 10 fluorescence detectors, Brightfield and SSC
- ISX Configuration
- CRTD 3rd floor south, room 3.112
- 0351-458-82368
- CMCB FCCF E-Mail
Spectral Imaging Cell Sorter
FACSDiscover S8 (BD)
- fully enclosed in a (Class II Type A2) Biosafety Cabinet
- 76 fluorescence detectors, 6 imaging detectors, FSC and SSC
- 5 lasers: UV (349nm), Violet (405nm), Blue (488nm), Yellow-Green (561nm), Red (637nm)
- sorting into different tubes, well plates and onto microscope slides
- Discover S8 Configuration
- CRTD 3rd floor south, room 3.113
- 0351-458-82369
- CMCB FCCF E-Mail
MACS Technology
autoMACS Pro (Miltenyi)
- MACS Microbead Technology for magnetic cell sorting
- walk-away cell isolation with automated labeling and separation
- fast and gentle isolation of virtually any cell type from any species
- CRTD 1st floor north, in front of room 1.229 (1.227)
- 0351-458-82138
- CMCB FCCF E-Mail
Analysis Computers
Computers on 3rd floor
- FACSDivaTM Software, Becton, Dickinson and Company (BD)
- FlowJoTM Software (for Windows) Version 10 - FlowJo, LLC & Becton, Dickinson and Company (BD)
- SpectroFlo(R) Software (Cytek)
- FlowlogicTM Software - Inivai Technologies
- IDEAS® Software - Amnis & Luminex