The hot gas test rig is located in the Merkelbau building (test hall in floor 1).
The test rig is operated at atmospheric pressure and temperatures of 1250 °C. Experimental possibilities are expanded by alternating thermal load (cold air – hot combustion gas) and superposition with servo-hydraulic induced mechanical stress.
Technical parameter
Hot gas temperature: | up to 1200°C | |
Cooling air temperature (for alternating thermal load tests): | ambient temperature (additional cooling by means of de-ionized water is possible via nozzles | |
Flow speed: | above 20 m/s (open cross section) | |
Maximum dimension of investigated specimen: | channel cross section (300 x 300 mm) and length of 500 mm | |
Superposition of mechanical stress: | static and alternating up to 100 kN Servo-hydraulic cylinder MTS, Electro-dynamic shaker (500 N) |
Applied measurement equipment and control
Besides conventional measurement equipment for monitoring test rig parameter we apply
- WAGO field bus data logging system (60 channels, pressure, temperature, mass flow, sample rate: 300 ms)
- Real time thermal imaging system VarioTHERMTM for measuring surface temperature distribution
- Siemens Logo SPS control system
- Optical strain measurement system (PROGRES C14 camera and analysis software ANALYSIS)
- Vibrometer