TTGWK
Test Section
- 10 or 6mm channel height
- 3 blades in the free stream
- Adjustable inlet incidence angle (±20°)
- Adjustable tailboards
- Optical accessibility for for different measurement systems
Flow characteristics
- High pressure tests up to 3 bar absolute inlet pressure
- Inlet Mach number ~0.25 (Re~5e5)
- Outlet Mach number up to ~1.2 (Re~1e6)
Parts
(1) Diffusor with diameter of 105.3mm up to 310 mm
(2) Round to rectangular transition
(3) Settling chamber 310mm x 310mm
(4) Nozzle to an area of 108mm x 108mm
(5) Small nozzle to an area of 10 or 6mm x 108mm
Testrig with an inlet flow area of 10 or 6mm x 128.8mm at 0° incidence