Equipment
The Chair of Electrochemistry has comprehensive, modern equipment. Analytical balances, drying cabinets, water baths, thermostats etc. are available for basic sample preparation.
Furthermore, for special measurement preparation of spectro-electrochemical experiments are available: Glovebox; actively damped optical bench; voltage/power supply and measuring instruments; temperature-controlled and rotatable measuring cells.
In particular, the following analytical instruments are available for spectro-electrochemical investigations:
Spectrometer
RAMAN spectrometer S&I Monovista CRS+
RAMAN spectrometer with microscope
- 7 excitation wavelengths
(405 nm / 442 nm / 514 nm / 561 nm / 595 nm / 660 nm / 785 nm) - Microscope Olympus BX51 WI
with xy-table Märzhäuser Scan IM 200x200 - Temperature-controlled measuring cell Linkam THMS600
- Variable optics
beam path can be decoupled - Bragg grating for 514 nm
ultra slim Rayleigh filter (5 cm-1), anti-STOKES scattering measurement possible - Mapping option
- SERS + SERRS measurements
IR spectrometer Bruker Tensor II
Bruker Tensor II
- Platinum ATR
- Liquid nitrogen-cooled MCT
- Room temperature DLaTGS
- Compressed air dryer Specken-Drumag
UV-VIS spectrometer Agilent Cary 60
Agilent Cary 60
Electrochemical Instruments
Potentiostat Gamry Reference 600
Gamry Reference 600
Max Current | ± 600 mA |
Current Ranges | 11 (60 pA - 600 mA) |
Current Ranges (w/Internal Gain applied) |
13 (600 fA - 600 mA) |
Min Voltage Resolution | 1 μV |
Min Current Resolution | 20 aA |
Max Applied Potential | ± 11 V |
Potentiostat Metrohm µAutolab III
Metrohm µAutolab III
Electrode connections | 2, 3 |
Potential range | +/- 5 V |
Compliance voltage | +/- 12 V |
Maximum current | +/- 80 mA |
Current ranges |
10 mA to 10 nA |
Potential accuracy | +/- 0.2 % |
Potential resolution | 3 µV |
Current accuracy | +/- 0.2 % |
Current resolution | 0.0003 % (of current range) |
Input impedance | > 100 GOhm |
Potentiostat bandwidth | 500 kHz |
Computer interface | USB |
Potentiostat Metrohm Autolab PGSTAT101
Metrohm Autolab PGSTAT101
Potential range | +/- 10 V; |
Maximum current | +/- 0.1 A |
Current ranges |
10 mA to 10 nA |
Potential accuracy | +/- 0.2 % |
Potential resolution | 3 µV |
Current accuracy | +/- 0.2 % |
Current resolution | 0.0003 % of current range |
Computer interface | USB |
Bi-Potentiostat Pine Wavedriver 20
PINE Wavedriver 20
Potential range | +/- 10 V; |
Maximum current | +/- 1 A |
Current ranges |
1 A to 100 nA |
Potential accuracy | +/- 0.2 % |
Potential resolution | 78 µV |
Current accuracy | +/- 0.05 % |
Current resolution | min. 3.13 pA |
Computer interface | USB |
Bi-Potentiostat Ametek Parstat 3000A-DX
Ametek Parstat 3000A-DX
Potential range | +/- 30 V; |
Maximum current | +/- 2 A |
Current ranges |
10 mA to 10 nA |
Potential accuracy | +/- 0.2 % |
Potential resolution | min. 305 nV |
Current accuracy | +/- 0.2 % |
Current resolution | min. 6.1 pA |
Computer interface | USB |
Rotating Disc Electrode
Metrohm Autolab RDE2 and others
- Rotating disc electrode
- Various electrode materials
Rotating Ring Disc Electrode
Pine E6 Change Disc RRDE (2x)
- Ring material: Platinum
- Disc material: Gold, Silver, Glassy carbon
changeable, diameter 5 mm - Temperature-controlled spectro-electrochemical cell