Measurement and test technology
Converter and sensors
- total frequency current converters for measurement ranges between 25 A and 2000 A
- total frequency voltage converters for measurement ranges between 50 V and 3000 V
- capacitive acceleration sensor
- measuring transducers for air pressure, air humidity and wind speed
- thermoelements for temperature measurements
- force sensors for 200 N up to 50 kN
This measurement technology can be connected to following measurement systems:
CRONOSflex CRFX-2000G-I
- 2000 kHz total sampling rate, 16 bit resolution, input voltage up to ± 10 V
- 8 digital inputs
- 8 digital inputs and outputs
- 4 analog outputs
- 4 incremental encoder inputs
- 2 * 8-channel margin measurement amplifier
- 8-channel universal measuring amplifier
- 4 intern potential-free high voltage probes
- CAN-bus-Interface
- GPS-mouse
- extended temperature range -20°C until +60°C
µ-MUSYCS-T:
- 80 kHz total sampling rate, 15 bit resolution, input voltage up to ± 10 V
- 32 digital inputs
- 32 analog single-ended inputs (thereof 13 differential operable)
- 4 incremental encoder inputs
- 2 intern potential-free high voltage probes up to 1000 V
- extended temperature range -20°C until +60°C
CHRONOS-PL-16:
- 400 kHz total sampling rate, 16 bit resolution, input voltage up to ± 10 V
- 16 digital inputs and outputs
- 32 differential analog inputs
- 4 incremental encoder inputs
- 4 intern potential-free high voltage probes up to 1000 V
- 1 Cansas-module for connection of e.g. 16 temperature sensors